| Part of the certification projects | Requirements for output port overload testing |
|
UL Certification |
Each power output pin of the output port should be overloaded as per the following regulations. Charge the built-in battery of the battery pack to a sufficient level according to the manufacturer's specifications. Cover the battery with a layer of gauze and place it on a softwood board. Cover the softwood board with a thin sheet of paper. Then load each power output pin of the output port to draw the maximum current, for at least 1 hour. The maximum current should be slightly lower than the trip point of any protection device, which is considered to be 110% of its rated current. Result: After completion, the gauze and paper should be intact. |
|
CQC Certification |
After the battery is fully charged according to the charging procedure specified by the manufacturer, it is charged at a constant current of 1.5 times the overcurrent protection current. The cycle test is conducted 500 times. Result: No fire, no explosion, no leakage. |