Welcome to the official website of ESTL!

Current location: Home > Test > Battery test > Other performance tests

Capacity test

Partial certification program

Battery capacity test requirements

UL certification

The cell of UL1642 needs to do 1/4 cycle of the total number of life cycles, and the capacity of the last time is not less than 90% of the rated capacity.

CQC certification

The battery is fully charged according to the charging procedure specified by the manufacturer, and left for 10 minutes, and then discharged according to the discharging procedure specified by the manufacturer. The capacity provided during discharge is the actual capacity of the battery (two charge and discharge cycles are required before the capacity test).

Result: The actual capacity of the battery sample should be greater than or equal to its rated capacity, otherwise it cannot be used as a typical sample for type testing.

CB certification

The battery is fully charged in accordance with the charging procedure specified by the manufacturer, and left for 10 minutes, and then discharged according to the discharging procedure specified by the manufacturer. The capacity provided during discharge is the actual battery.

Result: The actual capacity of the battery sample should be greater than or equal to its rated capacity, otherwise it cannot be used as a typical sample for type testing.


Next: None
Online message/ Messages
logo
Service Hotline13925598091
Address: 2st floor, B Area, Jinbaisheng Industrial Park, Headquarters 2 Road, Songshan Lake Hi-tech Industrial Development Zone, Dongguan City, Guangdong Pr., China. Telephone: 13925598091 Fax: 0769-8507-5898 Mailbox: net03@gtggroup.com
Wechat Public Number

Focus on Wechat
Public Number

Hotline

13925598091
13925598091
7*24-hour service hotline

QQ

Wechat

二维码Focus on Wechat
TOP