Welcome to the official website of ESTL!

Current location: Home > Test > Battery test > Protect circuit safety tests

Overcurrent charging protection

Partial certification program

Overcurrent charging protection test requirements

CQC certification

The battery samples were tested in the following sequence for 500 cycles:
    a) overvoltage charging;
    b) After the protection device is activated, it is allowed to stand for 1 min.
When overvoltage charging, the charging current is 1.5 times the overcurrent charging protection current (1.5Icp), and the charging voltage is the charging upper limit voltage (Uup).
The overcurrent charging protection circuit of the battery pack should be activated every cycle.


Online message/ Messages
logo
Service Hotline400-755-8988
Address: 2st floor, B Area, Jinbaisheng Industrial Park, Headquarters 2 Road, Songshan Lake Hi-tech Industrial Development Zone, Dongguan City, Guangdong Pr., China. Telephone: 13925598091 Fax: 0769-8507-5898 Mailbox: net03@gtggroup.com
Wechat Public Number

Focus on Wechat
Public Number

Hotline

400-755-8988
13925598091
7*24-hour service hotline

QQ

Wechat

二维码Focus on Wechat
TOP