Welcome to the official website of ESTL!

Current location: Home > News > Certification news > Certification information

CB to INMETRO Certification for Energy Storage Batteries Exported to Brazil: Guidelines & Key Points

Editor:ESTL Category:Certification information Release time:2026-11-16 Click volume:3

Ordinance INMETRO No. 140/2022 has been mandatory since May 2, 2024, bringing energy storage batteries for photovoltaic systems under regulatory control. Brazilian authorities do not automatically accept overseas test reports, yet existing CB reports held by manufacturers offer a pathway for certificate conversion — some test items may be exempt from full retesting.

Three core questions are addressed here: Is conversion eligible? What supplementary tests are required? How long is the lead time? This article explains each point in detail.

I. Scope of Acceptance for CB Reports

  1. Acceptable Portion. CB reports issued to standards such as IEC 62619 and IEC 62133-2 can serve as the technical foundation for safety-related items and avoid duplicate testing of identical test parameters.
  2. Non-substitutable Portion. Brazil-specific deviations and the long-duration performance tests specified in Annex B (ANEXO B) generally must be completed at INMETRO-accredited laboratories following ABNT NBR methods. The charge-discharge cycling test alone takes approximately 24–28 weeks. A full new test project typically takes around six months, which highlights the value of CB conversion.
  3. Decision Authority. Eligibility for substitution and the scope of accepted test data are reviewed case-by-case by INMETRO-accredited Certification Bodies (OCPs). There is no universal rule that guarantees conversion approval.

Additional Note: Energy Storage Testing holds CBTL (CB Testing Laboratory) accreditation and is authorized to issue CB reports under the IECEE framework. Its test reports are recognized by signatory bodies of the ILAC-MRA mutual recognition arrangement. Subject to OCP acceptance, these credentials help reduce redundant testing. The exact scope of acceptance is confirmed by Brazilian certification bodies according to product category and the applicable regulatory version.

II. Estimated Certification Lead Time

Route Features Reference Lead Time
Full new testing Complete 4 sets of tests per Annex B with multiple long-cycle test items Starting from approximately 6 months
CB report conversion Use CB report as technical baseline, perform supplementary tests per OCP review outcome Some completed cases achieved certification in around 6 weeks

Conversion saves time on repeated testing and procedural rework. Test durations are fixed by regulatory requirements; actual timelines vary depending on product design and OCP review decisions.

III. Compliance Requirements Beyond Testing

  1. Local Representative. Non-Brazilian manufacturers must hold the certificate via a Brazilian local agent or importer with a valid CNPJ tax ID.
  2. Portuguese Labelling. Permanent marking on the product is required, including manufacturer/importer name and CNPJ number, model, production date (DD/MM/YYYY), country of origin, batch or serial number. Battery cells must additionally indicate battery chemistry, application classification, rated voltage and rated capacity.
  3. Technical documentation and notarized documents shall be prepared in accordance with regulatory requirements.
  4. Post-certification Obligations. Surveillance audits apply during the validity period of the certificate. Any product modification or standard update must be declared.

IV. Pre-Assessment: Pre-Judge CB Report Usability

Instead of submitting reports blindly and taking risks, conduct a pre-evaluation first. Submit the first 3 pages of your CB report, and we will issue a Brazil Conversion Pre-Assessment Report within 2 working days. The assessment covers whether the CB report can be adopted directly, missing test items, supplementary testing scope, estimated lead time and cost range. The assessment is free of charge and carries no obligation for subsequent engagement.

In the past two years, we have supported multiple energy storage manufacturers with CB-to-INMETRO conversion projects. Several projects obtained certificates in roughly 6 weeks, including arrangements for Brazilian local representation and document notarization. Practical experience from these cases is integrated into our pre-assessment conclusions.

⚠ Disclaimer: Final acceptance of CB reports in lieu of INMETRO tests is subject to case-by-case review by INMETRO-accredited OCPs. Lead times quoted are based on past project references and subject to product design and review progress. Regulatory compliance shall follow the latest official publications.

Closing Remarks

The Brazilian market presents clear opportunities with well-defined compliance pathways. Clarify the acceptance boundary of your test reports, estimate timelines accurately and prepare all compliance documents in one go to keep your project on track. If you have questions about INMETRO certification for energy storage batteries exported to Brazil, feel free to contact Energy Storage Testing. We can evaluate your CB report, sort out the testing transition plan and lay a solid foundation for smooth certificate conversion.

Label: Brazil INMETRO certification for PV energy storage battery photovoltaic storage battery Brazil compliance Brazil local representative CNPJ CB report to INMETRO conversion IEC 62619 CB report Brazil METRO Ordinance 140/2022 ABNT NBR Annex B test CBTL laboratory ILAC MRA
logo
Service HotlineWhatsApp:+86 13925582920
Address: 2nd Floor, Block B, Jinbaisheng Industrial Park, No. 2 Zongbu Road, Songshan Lake High-tech Industrial Development Zone, Dongguan, Guangdong, China Telephone: +86 13925582920 Fax: +86-0769-85075898 Mailbox: net03@gtggroup.com
Wechat Public Number

Focus on Wechat
Public Number

WhatsApp

Email

Wechat

WeChat

WeChat QR

Scan to follow us on WeChat

TOP